Merge pull request #160 from SweVictor/feature/fix-ble-data-parsing
Fix BLE data parsing and move from toString-based Buffer parsing to int-based
This commit is contained in:
commit
2653119b85
2 changed files with 47 additions and 25 deletions
|
|
@ -25,20 +25,35 @@ const logFormat = printf((info) => {
|
|||
|
||||
/** Winston-based logger */
|
||||
class Logger {
|
||||
static shouldLogLookup = {};
|
||||
|
||||
constructor() {
|
||||
throw new Error('Please call createLogger instead');
|
||||
}
|
||||
|
||||
static getLogLevel() {
|
||||
const config = Configuration.getConfiguration();
|
||||
// eslint-disable-next-line max-len
|
||||
const level = (config.logLevel && LEVELS.find((l) => l.startsWith(config.logLevel[0].toLowerCase())))
|
||||
|| 'info';
|
||||
return level;
|
||||
}
|
||||
|
||||
static shouldLog(logLevel) {
|
||||
if (!Logger.shouldLogLookup[logLevel]) {
|
||||
// eslint-disable-next-line max-len
|
||||
Logger.shouldLogLookup[logLevel] = Logger.logLevels().levels[logLevel] <= Logger.logLevels().levels[Logger.getLogLevel()];
|
||||
}
|
||||
return Logger.shouldLogLookup[logLevel];
|
||||
}
|
||||
|
||||
/** Created logger will follow Winston createLogger, but
|
||||
* - add module name to logger
|
||||
* - swap debug/verbose levels and omit http to mimic HA standard
|
||||
* Levels (in order): error, warn, info, debug, verbose, silly
|
||||
* */
|
||||
static getLogger(moduleName) {
|
||||
const config = Configuration.getConfiguration();
|
||||
// eslint-disable-next-line max-len
|
||||
const level = (config.logLevel && LEVELS.find((l) => l.startsWith(config.logLevel[0].toLowerCase())))
|
||||
|| 'info';
|
||||
const level = Logger.getLogLevel();
|
||||
|
||||
const logger = winston.createLogger({
|
||||
format: combine(
|
||||
|
|
|
|||
|
|
@ -13,10 +13,10 @@ const LAST_DATA_UUID = '31ba0005-6085-4726-be45-040c957391b5';
|
|||
const AUTH_UUID = '31ba0009-6085-4726-be45-040c957391b5';
|
||||
const PING_UUID = '31ba000a-6085-4726-be45-040c957391b5';
|
||||
|
||||
const BLE_CMD_DIM_CHANGE = '00c8';
|
||||
const BLE_CMD_DIM2_CHANGE = '0098';
|
||||
const BLE_CMD_STATE_CHANGE = '0097';
|
||||
const BLE_CMD_SCENE_TRIG = '0021';
|
||||
const BLE_CMD_DIM_CHANGE = 0xc8;
|
||||
const BLE_CMD_DIM2_CHANGE = 0x98;
|
||||
const BLE_CMD_STATE_CHANGE = 0x97;
|
||||
const BLE_CMD_SCENE_TRIG = 0x21;
|
||||
|
||||
const BLUEZ_SERVICE_NAME = 'org.bluez';
|
||||
const DBUS_OM_INTERFACE = 'org.freedesktop.DBus.ObjectManager';
|
||||
|
|
@ -688,28 +688,31 @@ class PlejdService extends EventEmitter {
|
|||
const data = value.value;
|
||||
const decoded = this._encryptDecrypt(this.cryptoKey, this.plejdService.addr, data);
|
||||
|
||||
const deviceId = parseInt(decoded[0], 10);
|
||||
// What is bytes 2-3?
|
||||
const cmd = decoded.toString('hex', 3, 5);
|
||||
const state = parseInt(decoded.toString('hex', 5, 6), 10); // Overflows for command 0x001b, scene command
|
||||
// eslint-disable-next-line no-bitwise
|
||||
const data2 = parseInt(decoded.toString('hex', 6, 8), 16) >> 8;
|
||||
|
||||
if (decoded.length < 5) {
|
||||
if (Logger.shouldLog('debug')) {
|
||||
// decoded.toString() could potentially be expensive
|
||||
logger.debug(`Too short raw event ignored: ${decoded.toString('hex')}`);
|
||||
}
|
||||
// ignore the notification since too small
|
||||
return;
|
||||
}
|
||||
|
||||
const deviceId = decoded.readUInt8(0);
|
||||
// What is bytes 2-3?
|
||||
const cmd = decoded.readUInt8(4);
|
||||
const state = decoded.length > 5 ? decoded.readUInt8(5) : 0;
|
||||
// What is byte 6?
|
||||
const dim = decoded.length > 7 ? decoded.readUInt8(7) : 0;
|
||||
// Bytes 8-9 are sometimes present, what are they?
|
||||
|
||||
const deviceName = this._getDeviceName(deviceId);
|
||||
logger.verbose(`Raw event received: ${decoded.toString('hex')}`);
|
||||
logger.verbose(
|
||||
`Device ${deviceId}, cmd ${cmd.toString('hex')}, state ${state}, dim/data2 ${data2}`,
|
||||
);
|
||||
if (Logger.shouldLog('debug')) {
|
||||
// decoded.toString() could potentially be expensive
|
||||
logger.debug(`Raw event received: ${decoded.toString('hex')}`);
|
||||
logger.verbose(`Device ${deviceId}, cmd ${cmd.toString(16)}, state ${state}, dim ${dim}`);
|
||||
}
|
||||
|
||||
if (cmd === BLE_CMD_DIM_CHANGE || cmd === BLE_CMD_DIM2_CHANGE) {
|
||||
const dim = data2;
|
||||
|
||||
logger.debug(`${deviceName} (${deviceId}) got state+dim update. S: ${state}, D: ${dim}`);
|
||||
|
||||
this.emit('stateChanged', deviceId, {
|
||||
|
|
@ -733,7 +736,7 @@ class PlejdService extends EventEmitter {
|
|||
};
|
||||
logger.verbose(`All states: ${this.plejdDevices}`);
|
||||
} else if (cmd === BLE_CMD_SCENE_TRIG) {
|
||||
const sceneId = parseInt(decoded.toString('hex', 5, 6), 16);
|
||||
const sceneId = state;
|
||||
const sceneName = this._getDeviceName(sceneId);
|
||||
|
||||
logger.debug(
|
||||
|
|
@ -741,10 +744,14 @@ class PlejdService extends EventEmitter {
|
|||
);
|
||||
|
||||
this.emit('sceneTriggered', deviceId, sceneId);
|
||||
} else if (cmd === '001b') {
|
||||
} else if (cmd === 0x1b) {
|
||||
logger.silly('Command 001b seems to be some kind of often repeating ping/mesh data');
|
||||
} else {
|
||||
logger.verbose(`Command ${cmd.toString('hex')} unknown. Device ${deviceName} (${deviceId})`);
|
||||
logger.verbose(
|
||||
`Command ${cmd.toString(16)} unknown. ${decoded.toString(
|
||||
'hex',
|
||||
)}. Device ${deviceName} (${deviceId})`,
|
||||
);
|
||||
}
|
||||
}
|
||||
|
||||
|
|
|
|||